Selective Determination of Acidic Drugs in Water Samples Using Online Solid Phase Extraction Liquid Chromatography with Alginate Incorporated Multi-Walled Carbon Nanotubes as Extraction Sorbent
Nurzaimah Zaini @ Othman(1), Nor Suhaila Mohamad Hanapi(2*), Nor’ashikin Saim(3), Wan Nazihah Wan Ibrahim(4), Ahmad Lutfi Anis(5)
(1) Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
(2) Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
(3) Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
(4) Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor, Malaysia
(5) Faculty of Applied Sciences, Universiti Teknologi MARA, 94300 Kota Samarahan, Sarawak, Malaysia
(*) Corresponding Author
Abstract
A rapid and effective method is developed for selective determination of five selected acidic drugs (salicylic acid, naproxen, diclofenac, ibuprofen and mefenamic acid) in water samples by using online solid phase extraction (Online-SPE) prior to liquid chromatography diode array detector (LC-DAD) analysis. In this study, Alginate incorporated multi-walled carbon nanotubes (Alg-MWCNT) beads were prepared and utilized as solid phase extraction sorbent. Optimization of online SPE-LC operating parameters such as valve switching time, composition of acetonitrile and buffer pH was conducted using Box-Behnken Design of Response Surface Methodology (RSM) to evaluate the interactive effects of these three variables. Under the optimized conditions (valve switching time: 1.5 min, composition of acetonitrile: MSA, 60:40 and buffer pH: pH 2), the method showed good linearity (1–500 μg L−1) with coefficient of determination (R2) of 0.9971–0.9996 and low limits of detection ≤ 0.018 µg L–1. The method showed high relative recoveries in the range of 75–110% for river water and tap water samples, respectively with RSDs of ≤ 7.8 (n = 3). This method was successfully applied to the determination of acidic drugs in river and tap water samples. In addition, Alg-MWCNT sorbent offered high degree of selectivity and efficiency for online SPE-LC-DAD analysis.
Keywords
Full Text:
Full Text PDFReferences
[1] Białk-Bielińska, A., Kumirska, J., Borecka, M., Caban, M., Paszkiewicz, M., Pazdro, K., and Stepnowski, P., 2016, Selected analytical challenges in the determination of pharmaceuticals in drinking/marine waters and soil/sediment samples, J. Pharm. Biomed. Anal., 121, 271–296.
[2] Ji, Y., Du, Z., Zhang, H., and Zhang, Y., 2014, Rapid analysis of non-steroidal anti-inflammatory drugs in tap water and drinks by ionic liquid dispersive liquid–liquid microextraction coupled to ultra-high performance supercritical fluid chromatography, Anal. Methods, 6 (18), 7294–7304.
[3] Hanapi, N.S.M., Sanagi, M.M., Ibrahim, W.A.W., Saim, N., Ismail, A.K., Ibrahim, W.N.W., and Tahiruddin, S., 2015, Analysis of some anti-depressant drugs in aqueous samples using agarose film micro-electro driven membrane extraction, Der Pharma Chem., 7 (5), 235–242.
[4] Kosjek, T., Heath, E., and Krbavčič, A., 2005, Determination of non-steroidal anti-inflammatory drug (NSAIDs) residues in water samples, Environ. Int., 31 (5), 679–685.
[5] Payán, M.R., López, M.Á.B., Torres, R.F., Navarro, M.V., and Mochón, M.C., 2011, Electromembrane extraction (EME) and HPLC determination of non-steroidal anti-inflammatory drugs (NSAIDs) in wastewater samples, Talanta, 85 (1), 394–399.
[6] Zhang, Y., and Lee, H.K., 2012, Ionic liquid-based ultrasound-assisted dispersive liquid–liquid microextraction followed high-performance liquid chromatography for the determination of ultraviolet filters in environmental water samples, Anal. Chim. Acta, 750, 120–126.
[7] Yao, C., Li, T., Twu, P., Pitner, W.R., and Anderson, J.L., 2011, Selective extraction of emerging contaminants from water samples by dispersive liquid–liquid microextraction using functionalized ionic liquids, J. Chromatogr. A, 1218 (12), 1556–1566.
[8] Iuliani, P., Carlucci, G., and Marrone, A., 2010, Investigation of the HPLC response of NSAIDs by fractional experimental design and multivariate regression analysis. Response optimization and new retention parameters, J. Pharm. Biomed. Anal., 51 (1), 46–55.
[9] Hernando, M.D., Mezcua, M., Fernández-Alba, A.R., and Barceló, D., 2006, Environmental risk assessment of pharmaceutical residues in wastewater effluents, surface waters and sediments, Talanta, 69 (2), 334–342.
[10] Toledo-Neira, C., and Álvarez-Lueje, A., 2015, Ionic liquids for improving the extraction of NSAIDs in water samples using dispersive liquid–liquid microextraction by high performance liquid chromatography-diode array–fluorescence detection, Talanta, 134, 619–626.
[11] Zhang, S.Q., Bi, H.M., and Liu, C.J., 2007, Extraction of bio-active components from Rhodiola sachalinensis under ultrahigh hydrostatic pressure, Sep. Purif. Technol., 57 (2), 277–282.
[12] Hennion, M.C., 1999, Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography, J. Chromatogr. A, 856 (1-2), 3–54.
[13] Chen, L., Wang, H., Zeng, Q., Xu, Y., Sun, L., Xu, H., and Ding, L., 2009, On-line coupling of solid-phase extraction to liquid chromatography–A review, J. Chromatogr. Sci., 47 (8), 614–623.
[14] Jeon, O., Powell, C., Ahmed, S.M., and Alsberg, E., 2010, Biodegradable, photocrosslinked alginate hydrogels with independently tailorable physical properties and cell adhesivity, Tissue Eng. Part A, 16 (9), 2915–2925.
[15] Sahasathian, T., Praphairaksit, N., and Muangsin, N., 2010, Mucoadhesive and floating chitosan-coated alginate beads for the controlled gastric release of amoxicillin, Arch. Pharmacal Res., 33 (6), 889–899.
[16] Fernández-Ramos, C., Šatínský, D., Šmídová, B., and Solich, P., 2014, Analysis of trace organic compounds in environmental, food and biological matrices using large-volume sample injection in column-switching liquid chromatography, TrAC, Trends Anal. Chem., 62, 69–85.
[17] Sakai, S., and Kawakami, K., 2007, Synthesis and characterization of both ionically and enzymatically cross-linkable alginate, Acta Biomater, 3 (4), 495–501.
[18] Joddar, B., Garcia, E., Casas, A., and Stewart, C.M., 2016, Development of functionalized multi-walled carbon-nanotube-based alginate hydrogels for enabling biomimetic technologies, Sci. Rep., 6, 32456.
[19] Jie, G., Kongyin, Z., Xinxin, Z., Zhijiang, C., Min, C., Tian, C., and Junfu, W, 2015, Preparation and characterization of carboxyl multi-walled carbon nanotubes/calcium alginate composite hydrogel nano-filtration membrane, Mater. Lett., 157, 112–115.
[20] Pawar, S.N., and Edgar, K.J., 2012, Alginate derivatization: A review of chemistry, properties and applications, Biomaterials, 33 (11), 3279–3305.
[21] Şolpan, D., and Torun, M., 2005, Investigation of complex formation between (sodium alginate/acrylamide) semi-interpenetrating polymer networks and lead, cadmium, nickel ions, Colloids Surf., A, 268 (1-3), 12–18.
[22] Sangwichien, C., Aranovich, G.L., and Donohue, M.D., 2002, Density functional theory predictions of adsorption isotherms with hysteresis loops, Colloids Surf., A, 206 (1-3), 313–320.
[23] Fugetsu, B., Satoh, S., Iles, A., Tanaka, K., Nishi, N., and Watari, F., 2004, Encapsulation of multi-walled carbon nanotubes (MWCNTs) in Ba2+-alginate to form coated micro-beads and their application to the pre-concentration/elimination of dibenzo-p-dioxin, dibenzofuran, and biphenyl from contaminated water, Analyst, 129 (7), 565–566.
[24] Luo, Y.B., Zheng, H.B., Wang, J.X., Gao, Q., Yu, Q.W., and Feng, Y.Q., 2011, An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples, Talanta, 86, 103–08.
[25] Manzo, V., Honda, L., Navarro, O., Ascar, L., and Richter, P., 2014, Microextraction of non-steroidal anti-inflammatory drugs from waste water samples by rotating-disk sorptive extraction, Talanta, 128, 486–492.
[26] Liu, L., Wen, Y.B., Liu, K.N., Sun, L., Wu, M., Han, G.F., Lu, Y.X., Wang, Q.M., and Yin, Z., 2013, Optimization of on-line solid phase extraction and HPLC conditions using response surface methodology for determination of WM-5 in mouse plasma and its application to pharmacokinetic study, J. Chromatogr. B, 923-924, 8–15.
[27] Ahmad, M.A., and Alrozi, R., 2010, Optimization of preparation conditions for mangosteen peel-based activated carbons for the removal of Remazol Brilliant Blue R using response surface methodology, Chem. Eng. J., 165 (3), 883–890.
[28] Joglekar, A.M., and May, A.T., 1987, Product excellence through design of experiments, Cereal Food World, 32, 857–868.
[29] Funari, C.S., Carneiro, R.L., Cavalheiro, A.J., and Hilder, E.F., 2014, A trade off between separation, detection and sustainability in liquid chromatographic fingerprinting, J. Chromatogr. A, 1354, 34–42.
[30] LoBrutto, R., Jones, A., Kazakevich, Y.V., and McNair, H.M., 2001, Effect of the eluent pH and acidic modifiers in high-performance liquid chromatography retention of basic analytes, J. Chromatogr. A, 913 (1-2), 173–187.
[31] Fugetsu, B., Satoh, S., Shiba, T., Mizutani, T., Lin, Y.B., Terui, N., Nodasaka, Y., Sasa, K., Shimizu, K., Akasaka, T., Shindoh, M., Shibata, K., Yokoyama, A., More, M., Tanaka, K., Sato, Y., Tohji, K., Tanaka, S., Nishi, N., and Watari, F., 2004, Caged multiwalled carbon nanotubes as the adsorbents for affinity-based elimination of ionic dyes, Environ. Sci. Technol., 38 (24), 6890–6896.
[32] Kot-Wasik, A., Dębska, J., Wasik, A., and Namieśnik, J., 2006, Determination of non-steroidal anti-inflammatory drugs in natural waters using off-line and on-line SPE followed by LC coupled with DAD-MS, Chromatographia, 64 (1-2), 13–21.
[33] Paíga, P., Lolić, A., Hellebuyck, F., Santos, L.H.M.L.M., Correia, M., and Delerue-Matos, C., 2015, Development of a SPE–UHPLC–MS/MS methodology for the determination of non-steroidal anti-inflammatory and analgesic pharmaceuticals in seawater, J. Pharm. Biomed. Anal., 106, 61–70.
DOI: https://doi.org/10.22146/ijc.43703
Article Metrics
Abstract views : 2548 | views : 2340Copyright (c) 2019 Indonesian Journal of Chemistry
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.
View The Statistics of Indones. J. Chem.