THE EFFECT OF PVC-BASED MEMBRANE COMPOSITION AND Zn(II), Cd(II) AND Pb(II) INTERFERING IONS TO Hg(II) ION SELECTIVE ELECTRODE (ISE) PERFORMANCE BY USING DBA218C6 IONOPHORE

https://doi.org/10.22146/ijc.21768

Abd. Wahid Wahab(1*)

(1) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Hasanuddin University, Makassar
(*) Corresponding Author

Abstract


The effect of PVC (Polyvinylchloride)-Based Membrane Composition to Ion Selective Electrode (ISE)-Hg(II) Performance using Ionophore DBA218C6 (N,N'-Dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclo octadecane),  Plasticizer NPOE (Nitrophenyl Octhyl Ether), Anionic Site KTCPB (Potassium Tetrakis (4-chloro phenyl) borate) have been performed. Membrane compositions used were:(a) PVC (30 mg), NPOE (60 mg), DBA218C6(6 mg) and KTCPB (4 mg); (b) PVC(30 mg), NPOE (60 mg), DBA218C6(7 mg) and KTCPB (3 mg); (c) PVC (30 mg), NPOE (59 mg), DBA218C6 (8 mg) and KTCPB( 3 mg). The concentration range of interference ions Zn(II), Cd(II) and Pb(II)  were 1.0 x 10-3 - 1.0 x 10-1 M. ISE-Hg(II) performance for membrane composition of 30 : 60 : 6 : 4 was 26.34 mV per decade (Nernstian Slope value) on Hg(II) concentration range of 1.0x10-6 - 1.0 x 10-1 M , membrane composition of 30 : 60 : 7 : 3 was 27.71 mV per decade on Hg(II) concentration range of 1.0 x10-6 - 1.0 x10-1 M, and membrane composition of 30 : 59 : 8 : 3 was 28.52 mV per decade on Hg(II) concentration range of  1.0 x10-6 - 1.0 x10-1 M with activity between pH 1.0-3.0. The concentration of interference ions : Zn(II), Cd(II) and Pb(II) in the range of 1.0 x 10-3 - 1.0 x 10-1 M with the ratio of the primary ion to interference ions of 4 : 1 gave real effect. As results, selectivities and sensitivities between ISE-Hg(II) and Ionophore DBA218C6 could be determined by PVC-Based Membrane Composition and the effect of Zn(II), Cd(II) and Pb(II)  interference ions was observed in the concentration of 1,0 x10-3 - 1,0 x10-1 M.


Keywords


membrane composition effect; ionophore DBA218C6; ISE-Hg(II)

Full Text:

Full Text Pdf


References

[1] Janata, J., Josowiwicsz., V. and De Vaney, D.M., 1998, Anal.Chem. 70, 179R-208R.

[2] Atikah, 1994. Pembuatan dan Karakterisasi ESI Nitrat Tipe Kawat Terlapis. Tesis Pasca Sarjana, Institut Teknologi Bandung, Bandung.

[3] Lakshminarayanaiah, N., 1976, Membrane Electrodes. Academic Press, New York.

[4] Bailey, P.L., 1976, Analysis with Ion Selective Electrodes. Heyden & Son Ltd, London

[5] Nurdin, E., 2002, Studi Kinerja ESI Kadmium dengan Ionofor Ligan 3-Metil-1-(4-Nitrofenil)-4-(4-Oktilbenzoil) Pirazol-5-on. Disertasi, FMIPA-Universitas Padjajaran, Bandung.

[6] Singh, A.K., Saxena, P., and Singh, R., 2005, Anal. Sciences, 21.179-181.

[7] Rahmat, M., 2002, Pembuatan dan Studi Kinerja Elektroda Selektif Ion Kobal(II) dengan Bahan Aktif Di(2-Ethhylhexyl) PhosphoricAcid (D2EHPA). Program Studi Kimia, Pascasarjana Institut Teknologi Bandung, Bandung.

[8] Fakhari, A.R., Ganjali, M.R., and Shamsipur, M., 1997, J. Anal. Chem., 69, 3693 – 3696.

[9] Kuswandi, B., 2003, Jurnal Ilmu Dasar, 4, 2, 88-98.

[10] Gennet, T., and Purdy, W.C,1991, Am. Lab., 23(6) 60.

[11] Wang, J., Tian, B., Rogers, K.R., 1998, Anal.Chem.70.1682

[12] Janata, J., 2001, Anal Chem., 73. 150A.



DOI: https://doi.org/10.22146/ijc.21768

Article Metrics

Abstract views : 1388 | views : 1512


Copyright (c) 2010 Indonesian Journal of Chemistry

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

 


Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.

Web
Analytics View The Statistics of Indones. J. Chem.