DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

https://doi.org/10.22146/ijc.21755

Sunardi Sunardi(1*), Muryono Muryono(2)

(1) Center of Accelerator Technology and Material Process, National Nuclear Energy Agency, Kompleks Babarsari, Yogyakarta, 55281
(2) Center of Accelerator Technology and Material Process, National Nuclear Energy Agency, Kompleks Babarsari, Yogyakarta, 55281
(*) Corresponding Author

Abstract


Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec).  At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and  experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are  2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively.  The data  indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator.


Keywords


limit detection; AANC; neutron generator

Full Text:

Full Text Pdf


References

[1] Anonim, 1991, Pedoman 01-1991, Persyaratan Umum Kemampuan Laboratorium Kalibrasi dan Laboratorium Penguji, BSN, Jakarta.

[2] Nargolwalla, S.S, and Prsybylowicz, E.P, 1973, Activation Analysis with Neutron Generators, John Wiley and Sons, New York.

[3] Csikai, J., 1987, CRC. Handbook of Fast Neutron Generators, Vol 1, CRC Press Inc., New York.

[4] Kamioki H., 2004, Joint Training Course on Application of Nuclear Technique in Industry and Environment Available for the Safety of Nuclear Facility, Pusdiklat Batan, Jakarta.

[5] Iyer, R.K., 1983, Evaluation of Analitical Data in Activation Analysis, Bombay.

[6] Sunardi, Samin, and Nuraini E., 2005, Validasi Metode Analisis Aktivasi Neutron Cepat (AANC) untuk Unsur N, P, K, Si, Al, Cu, Cd, Fe Menggunakan Generator Neutron, Prosiding PPI- PDIPTN, P3TM BATAN, Yogyakarta.

[7] Pasikah, 1998, Optimasi Parameter Spetroskopi Gamma dengan Detektor Germanium Kemurnian Tinggi HPGe, Skripsi Jurusan Fisika, FMIPA, Universitas Riau, Pekanbaru.

[8] Kukuh S., 1999, Validasi Metode, Buku Panduan Pelatihan Asessor, BSN, Jakarta.



DOI: https://doi.org/10.22146/ijc.21755

Article Metrics

Abstract views : 1217 | views : 3533


Copyright (c) 2010 Indonesian Journal of Chemistry

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

 


Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.

Web
Analytics View The Statistics of Indones. J. Chem.