The iodate-selective electrode based on the principle of precipitation reaction could be made by coating the platinum wire with silver iodate (AgIO3). In this research was carried out optimization the iodate-selective electrode using chitosan membrane as an AgIO3 support. The AgIO3 were added in the 2 mL 1% chitosan solution, is 0.5 to 2.5 % (w/v). The thickness of the membrane used is 6 to 12 µm. The electrode cell potential is measured against Ag/AgCl electrode as a reference electrode. The optimum electrode performance was at 2.0 % of AgIO3 with thickness a membrane of 10 µm. The iodate-selective electrode has a Nernstian factor is 52.96 mV/decade and a response time of 10 seconds. The concentration range was determined from 10-3 M to 10-1 M and the detection limit is 1.12 x 10-5 M.
Keywords
Full Text:
Full Text PDFReferences
[1] Mannar, M.G.V. and Dunn., T., 1995, Choice and Dosage of Iodine Compound for Salt Iodization, http://www.ajur.uni.edu
[2] Djokomoeldjanto, R., 1993, Hipotiroidi di Daerah Defisiensi Iodium, Kumpulan Naskah Simposium GAKI, Badan Penerbit Universitas Diponegoro, Semarang, 35-46.
[3] Muhilal, Jalal and Hardiansyah, 1998, Angka Kecukupan Gizi Rata-Rata yang Dianjurkan, Widyakarya Pangan dan Gizi Nasional VI, LIPI, Jakarta.
[4] Mulyasuryani, A., 2006, The Coated Wire Silver/Silver Iodate As An Ion Selective Iodate Electrode, The 2006 Seminar on Analytical Chemistry, Yogyakarta
[5] Oshita, K., Oshima, M., Gao, Y., Lee, K.H., Motomizu, Sh., 2002, Anal. Sci., 18, 1121 -1125.
[6] Rohindra, D.R., Nand, A.V., Khurma, J.R., 2005, Swelling Properties of Chitosan Hydrogel, Dept. Chem. Univ. South Pacific, Fiji.
[7] Pungor, E., 2001, Sensors, 1, 1 – 12
[8] Wang, J., 2001, Analytical Electrochemistry, 2rd ed., VCH Publisher, Inc., 133 – 160.
[9] Rundle, C.C, 2006, A Beginners Guide to Ion-Selective Electrode Measurements, Nico2000 Ltd, London, UK, http://www.studysphere.com/
DOI: https://doi.org/10.22146/ijc.21670
Article Metrics
Abstract views : 1788 | views : 5383Copyright (c) 2010 Indonesian Journal of Chemistry
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.
View The Statistics of Indones. J. Chem.