Designing PDAM Banyumas Conductivity and Total Dissolved Solids Monitoring System Based on IoT

  • Indah Permatasari Institut Teknologi Telkom Purwokerto
  • Nia Annisa Ferani Tanjung Institut Teknologi Telkom Purwokerto
  • Nur Afifah Zen Institut Teknologi Telkom Purwokerto
Keywords: Kualitas Air, Konduktivitas, TDS, PDAM, HTTP, MQTT

Abstract

PDAM is a company engaged in the distribution of clean water for the community. Some Indonesian people have become PDAM water customers to meet their water needs for their daily activities. Water quality is an important issue because it is closely related to health. In this paper, the design of the water quality monitoring system in PDAM Banyumas based on IoT is carried out by reviewing the parameters of electrical conductivity (EC) and dissolved solids (TDS). The result of measurement data can be accessed via the Android App on smartphone. The application is designed using HTTP and MQTT protocols. HTTP protocol is used on the user interface to retrieve the last measurement data. Meanwhile, the MQTT protocol is used to update measurement data so that the data transmission process is faster. The system will send notification via telegram if the water quality is below quality standard. The measurement accuracy test is done by comparing the monitoring device with the certified measuring instrument on samples of bottled drinking water and PDAM water. The results show that the performance of the designed monitoring device was 97.31% and the quality of the PDAM Banyumas water is very stable and safe for consumption.

References

P. Hermiyanti dan E.T. Wulandari, "Gambaran Sisa Klor dan MPN Caliform Jaringan Distribusi Air PDAM," Jurnal Media Kesehatan, Vol. 10, No. 2, hal. 102-204, 2017.

Y. Kusumawardani dan W. Astuti, "Evaluasi Pengelolaan Sistem Penyediaan Air Bersih di PDAM Kota Madiun," Jurnal Neo Teknika, Vol. 4, No. 1, hal. 1-10, 2018.

B. Haq dan A. Masduqi, "Sistem Distribusi Air Siap Minum PDAM Kota Malang: Studi Kasus Kecamatan Blimbing," Jurnal Teknik POMITS, Vol. 3, No. 2, hal. D-183-187, 2014.

S. Choo-in, "The Relationship Between the Total Dissolved Solids and the Conductivity Value of Drinking Water, Surface Water and Wastewater," The 2019 International Academic Research Conference in Amsterdam, 2019, hal. 11-16.

I. Fadhilah dan Afdal, "Analisis Hubungan Konduktivitas Listrik dengan Total Dissolved Solid (TDS) dan Temperature pada Beberapa Jenis Air," Jurnal Fisika Unand, Vol. 5, No. 1, hal. 85-93, 2016.

N. Rahmanian, S.H. Bt. Ali, M. Homayoonfard, N.J. Ali, M. Rehan, Y. Sadef, dan A.S. Nizami," Analysis of Physiochemical Parameters to Evaluate the Drinking Water Quality in the State of Perak, Malaysia," Journal of Chemistry, Vol. 2015, hal. 1-10, 2015.

T. Akter, F.T. Jhohura, F. Akter, T.R. Chowdury, S.K. Mistry, D. Dey, M.K. Barua, M.A. Islam, dan M. Rahman, "Water Quality Index for Measuring Drinking Water Quality in Rural Bangladesh: A Cross-Sectional Study," Journal of Health, Population and Nutrition, Vol. 35, No. 4, hal. 1-12, 2016.

M.S.U. Chowdury, T.B. Emran, S. Ghosh, A. Pathak, M.M. Alam, N. Absar, K. Andersson, dan M.S. Hossain, "IoT Based Real-time River Water Quality Monitoring System," The 16th International Conference on Mobile Systems and Pervasive Computing (MobiSPC), 2019, hal. 161-168.

C. Maple, "Security and Privacy in the Internet of Things," Journal of Cyber Policy, Vol. 2, No. 2, hal. 155-184, 2017.

D.J. Amalraj, S. Banumathi dan J.J. John, "IoT Sensors and Applications: A Survey," International Journal of Scientific & Technology Research, Vol. 8, No. 8, hal. 998-1003, Agu. 2019.

R.A. Atmoko, R. Riantini, dan M.K. Hasin, "IoT Real Time Data Acquisition Using MQTT Protocol," International Conference on Physical Instrumentation and Advanced Materials, 2017, hal. 1-6.

F. Mehmood, S. Ahmad, dan D. Kim, "Design and Implementation of Automation Appliances Control Based on MVC Model Using Distributed MQTT Broker in CoT Networks," International Journal of Innovative Technology and Exploring Engineering (IJITEE), Vol. 8, No. 3C, hal. 262-269, 2019.

A.F. Rusydi, "Correlation Between Conductivity and Total Dissolved Solid in Various Type of Water: A Review," Earth and Environmental Science, 2017, hal. 1-6.

M.B.W. Harini, P.Y. Merucahyo, dan A.T. Priantoro, "Alat Ukur Konduktivitas Air Sungai pada Sistem Monitoring Kualitas Air Kolam," Prosiding Seminar RiTekTra, 2013, hal. 187-190.

T. Yokotani dan Y. Sasaki, "Comparison with HTTP and MQTT on Required Network Resources for IoT," The 2016 International Conference on Control, Electronic, Renewable Energy and Communication (ICCEREC), 2016, hal. 1-6.

R. Parlika dan A. Pratama, "The Online Test Application Uses Telegram Bots Version 1.0," Journal of Physics: Conference Series, Vol. 1569, No. 2, hal. 1-7, 2019.

"Keputusan Menteri Kesehatan No. 32 Tahun 2017," Kementerian Kesehatan Republik Indonesia, 2017.

Published
2021-02-25
How to Cite
Indah Permatasari, Nia Annisa Ferani Tanjung, & Nur Afifah Zen. (2021). Designing PDAM Banyumas Conductivity and Total Dissolved Solids Monitoring System Based on IoT. Jurnal Nasional Teknik Elektro Dan Teknologi Informasi, 10(1), 25-31. https://doi.org/10.22146/jnteti.v10i1.1023
Section
Articles