Analisis laik sehat dan kualitas mikrobiologis air minum isi ulang di Kecamatan Ligung, Majalengka
Iman Iman(1*), Titik Nuryastuti(2), Lucky Herawati(3)
(1) Departemen Perilaku Kesehatan, Lingkungan dan Kedokteran Sosial, Fakultas Kedokteran, Universitas Gadjah Mada
(2) Departemen Mikrobiologi, Fakultas Kedokteran, Universitas Gadjah Mada
(3) Politeknik Kesehatan Kementerian Kesehatan Yogyakarta
(*) Corresponding Author
Abstract
Purpose
The purpose of this study was to explore the relationship of feasibility analysis of health indicators with the microbiological quality of refill drinking water.
Method
The study used a descriptive design with a cross-sectional analytic approach. The dependent variable was the microbiological quality of refill drinking water. The independent variables were the following health indicators: raw water quality, equipment and processing method, operator behavior, and sanitation of depot building.
Results
There were significant correlations between variables of health indicator, equipment and processing method with E.coli microbiological quality. There was no significant correlation between quality of raw water, behavior of the operator, and sanitation buildings with microbiological quality.
Conclusion
Almost fifty percent of DAMIU refill drinking water is not qualified for microbiological quality of coliform and microbiological quality of Escheria coli. The most dominant factors affecting microbiological quality of drinking water refills are equipment and processing.
Keywords
Full Text:
PDF (Bahasa Indonesia)References
- Purwana. Pedoman dan pengawasan Higiene Sanitasi Depot Air Minum. Jakarta; 2003.
- Rahayu CS, Setiani O, Nurjazuli N. Faktor Risiko Pencemaran Mikrobiologi pada Air Minum Isi Ulang di Kabupaten Tegal. J Kesehat Lingkung Indones. 2013 Dec 18;12(1):1–9.
- Munandar AH. Modul Pelatihan Pemantauan Kualitas Kesehatan Lingkungan (On Site Rapid Assesment). Jakarta; 2012.
- Suprihatin B, Adriyani R. Higiene sanitasi depot air minum isi ulang di Kecamatan Tanjung Redep Kabupaten Berau Kalimantan Timur. J Kesehat Lingkung. 2008;4(2).
- Majalengka DKK. Profil Kesehatan Kabupaten Majalengka. Majalengka; 2013.
- Puskesmas Lingung. Evaluasi Puskesmas Ligung Tahun 2013. Majalengka; 2013.
- Athena, Sukar, Hendro, Anwar. Pengaruh pengolahan air di depot air minum isi ulang dalam menormalkan derajat keasaman. Media Penelit dan Pengemb Kesehaan. 2005;15(2).
- Dirjen PP & PL Kementerian Kesehatan RI. Pedoman Pelaksanaan Penyelenggaraan Hygiene Sanitasi Depot Air Minum. Jakarta; 2010.
- Saleh R, Setiani O, Nurjazuli N. Efektivitas Unit Pengolahan Air di Depot Air Minum Isi Ulang (DAMIU) Dalam Menurunkan Kadar Logam (Fe, Mn) dan Mikroba di Kota Pekalongan. J Kesehat Lingkung. 2013 Dec 18;12(1):75–81.
- Asfawi S. Faktor yang Berhubungan dengan Kualitas Mikrobiologi Air Minum Isi Ulang pada Tingkat Produsen di Kota Semarang Tahun 2004. Universitas Negeri Diponegoro; 2004.
- Mirza MN. Hygiene Sanitasi dan jumlah Coliform air minum. Kesmas. 2014;9(2).
DOI: https://doi.org/10.22146/bkm.7606
Article Metrics
Abstract views : 1427 | views : 2087Refbacks
- There are currently no refbacks.
Copyright (c) 2016 Berita Kedokteran Masyarakat
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Berita Kedokteran Masyarakat ISSN 0215-1936 (PRINT), ISSN: 2614-8412 (ONLINE).