Deteksi Karakteristik Peluruhan Radionuklida Medis 99Mo Untuk Memperoleh 99mTc Menggunakan Spektrometer Gamma dengan Sumber Standar Cair Campuran 133Ba dan 152Eu

https://doi.org/10.22146/jfi.v24i2.54405

Mawar - Mawar(1*), Sri Dewi Astuti(2), Siska Febriana(3)

(1) Hasanuddin University
(2) Hasanuddin University
(3) Hasanuddin University
(*) Corresponding Author

Abstract


Technetium-99m (99mTc) is a subsidiary of metastable 99Mo with a half-life of 6 hours. The relatively short half-life, causing 99mTc widely used for diagnostic purposes in nuclear medicine, especially in bone scanning for a faster decay. This research aims to determine the optimal time to product formation of 99mTc until elution profiles have detected 99Mo energy. The instrument used is the 99Mo/99mTc generator with standard sources 133Ba and 152Eu liquid mixture. The results obtained showed that 99mTc radioisotope production is still good until the third day elution 99Mo, whereas in the fourth to ninth day 99Mo energy detected on the decline, so that the activity of the 99mTc resulting product cannot be used for diagnosis.


Keywords


Molybdenum-99; Technetium-99m; Gamma Spectrometer; 99Mo/99mTc Generator

Full Text:

PDF


References

  1. Palupi AFN, Raka GB, Rahmadini FB. Aplikasi Radioisotop Penggunaan 99mTc untuk Bone Scan. Surabaya: Institut Teknologi Sepuluh November; 2017.

  2. Adang HG, Mutalib A, Hotman L, Rohadi A, Sriyono MS, Yono S,
    et al. Unjuk Kerja Generator Mo-99/Tc-99m berbasis PZC (poly zircinium compound) menggunakan Mo-99 hasil aktivasi neutron dari mo alam dengan aktivitas Mo-99> 5 Ci. Yogyakarta: Pusat Teknologi Akselerator dan Proses Bahan-BATAN. 2011;p. 44–51.

  3. Awaludin R. Radioisotop Teknesium-99m dan kegunaannya. Buletin Alara. 2011;13(2).

  4. Uzunov N, Yordanova G, Salim S, Stancheva N, Mineva V, Mel ́endez-Alafort L, et al. Quality assurance of Mo-99/Tc-99m radionuclide generators. Acta Scientifica Naturalis. 2018;5(1):40–47.

  5. Putri HH. Proses pemisahan dan pemurnian 99mTc dari 99Mo hasil aktivasi Neutron dengan menggunakan Kromatografi kolom Alumina. UIN Syarif Hidayatullah; 2013.

  6. Marlina M, Sriyono S, Lestari E, Abidin A, Setiawan H, Kadarisman K. Desain dan Performa Prototipe Generator 99Mo/99mTc dengan Kolom Material Berbasis Zirkonium dan Kolom Alumina. Jurnal kimia dan Kemasan. 2016;38(2):93–102.

  7. Wahyudi W, Iskandar D, Marjanto D. Pengaruh Matriks Terhadap Sistem Pencacahan Sampel Menggunakan Spektrometer Gamma. In: Jurnal Forum Nuklir. vol. 1; 2017. p. 65–77.

  8. Maskur M, Adang HG, Sarmini E, Tahyan Y, Kurniasih D. Uji Banding Antar Laboratorium dalam Pengukuran Radioaktivitas Menggunakan Spektrometer Gamma. In: Jurnal Forum Nuklir. vol. 8; 2017. p. 190–199.

  9. Luhur N, Kadarusmanto K, Subiharto S. Uji Banding Spektrometer Gamma dengan Metode Analisis. REAKTOR-Buletin Pengelolaan Reaktor Nuklir. 2013;10(1).

  10. Sugino, Tulisna, Sanusi A, Sugito. Validasi Spektrometer Gamma di Laboratorium Spektroskopi Pusdiklat BATAN. In: Prosiding Seminar Nasional AAN; 2010. p. 111–115.

  11. Mettler FA, Guiberteau MJ. Essentials of Nuclear Medicine and Molecular Imaging E-Book. Elsevier Health Sciences; 2018.



DOI: https://doi.org/10.22146/jfi.v24i2.54405

Article Metrics

Abstract views : 3373 | views : 3218

Refbacks

  • There are currently no refbacks.


Copyright (c) 2020 Mawar - Mawar, Sri Dewi Astuti, Siska Febriana

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

JFI Editorial Office

Departement of Physics, Faculty of Mathematics and Natural Sciences, Universitas Gadjah Mada

Sekip Utara PO BOX BLS 21, 55281, Yogyakarta, Indonesia

Email: jfi.mipa@ugm.ac.id

JFI is indexed by:


Creative Commons License
Jurnal Fisika Indonesia, its website and the articles published are licensed under a Creative Commons Attribution-ShareAlike 4.0 International License

Social media icon made by Freepik from www.flaticon.com

Social media icon made by Freepik from www.flaticon.com

web
analytics View My Stats