Separation of Nickellrom Plating Solution by Sulluration TreatmentT

https://doi.org/10.22146/ajche.50835

T. Fukuta(1*), T. Ito(2), K. Sawada(3), Yoshihiro Kojima(4), Eileen C. Bernardo(5), Hitoki Matsuda(6), K. Yagishita(7)

(1) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(2) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(3) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(4) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(5) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(6) Research Center for Advanced Waste and Emission Management Nagoya University, Furo-cho, Chikusa-ku Nagoya 464-8603 JAPAN
(7) Sanshin Mfg. Co., Ltd., 1-2 Kifuneura Haguro Inuyama, 484-{)894 JAPAN
(*) Corresponding Author

Abstract


Precipitation by sulfuration of nickel was used to recover nickel from the waste plating solution. Three kinds of sulfurating agents-sodium sulfide (Na2S), sodium disulfide (Na2S2),and sodium tetrasulfide (Na2S4)-were compared for the sulfuration behavior and the precipitation characteristics of the nickel sulfide (NiS) produced. Results showed that the nickel concentration in the filtrate was reduced from the initial concentration of 100 mRN/L to about 0.594-3.37 mRN/L with the addition of each sulfurating agent. The average specific filtration resistance of the slurry produced by adding each sulfurating agent was smaller than that in the nickel hydroxide (NiOH) slurry. In particular, the average specific filtration resistance of the slurry produced by adding Na2S4 was greatly reduced under controlled pH values of 7:t 1. The good filtration property obtained from the proposed sulfuration treatment was attributed to the larger particle-size distribution of NiS produced by the sulfuration agent Na2S4. It was further confirmed that the proposed sulfuration treatment using Na2S was applicable for the separation of nickel, zinc, and copper in mixed-metal solutions.

Keywords


Average specific filtration resistance, electroplating solution, nickel sulfide (NiS), polysulfide, sulfuration, and wastewater treatment.

Full Text:

PDF


References

  1. Kosaka, Y. (1997). “Treatment of plating wastewater," Hyoumen Gijutsu, 48, 242–45.
  2. The Chemical Society of Japan. (1993). Kagaku binran kisohen, 4th ed., Maruzen, Tokyo 1167-71.
  3. Coulson, J. M., and Richardson, J. F. (1968). Chemical engineering, vol. 2, Pergamon Press, London. 48-106. Federation of Electroplating Industry Association of Japan. (1993). Report of comprehensive recycle of valuable metals. Meux., E. et al. (1995). "Inertage des déchets sidérurgiques par sulfuration," La Revue de Métallurgie-CIT, 823–33.
  4. The Society of Chemical Engineers, Japan. (1999). Kagaku Kogaku Binran, Maruzen, Tokyo. 789-819.
  5. Tels, M. (1987). "Advances in treating heavy metals containing wastes," Resources and Conservation, 14, 71-92.



DOI: https://doi.org/10.22146/ajche.50835

Article Metrics

Abstract views : 1195 | views : 770

Refbacks

  • There are currently no refbacks.


ASEAN Journal of Chemical Engineering  (print ISSN 1655-4418; online ISSN 2655-5409) is published by Chemical Engineering Department, Faculty of Engineering, Universitas Gadjah Mada.