Nickel ion release of niti archwire in variations of immersion time and toothpaste

https://doi.org/10.22146/majkedgiind.65712

Syamsiar Cahayati(1), Lusiana Batubara(2), Diah Ajeng Purbaningrum(3), Budi Wibowo(4*)

(1) Department of Dentistry, Faculty of Medicine, Universitas Diponegoro, Semarang, Central Java
(2) Department of Medical Biology and Biochemistry, Faculty of Medicine, Universitas Diponegoro, Semarang, Central Java
(3) Department of Dentistry, Faculty of Medicine, Universitas Diponegoro, Semarang, Central Java
(4) Department of Dentistry, Faculty of Medicine, Universitas Diponegoro, Semarang, Central Java
(*) Corresponding Author

Abstract


Nickel-titanium archwires in orthodontic wires have nickel ion releases. The use toothpaste and saliva immersion time may cause its releases. This study aims to prove the difference and interaction between immersion time and toothpaste variations towards the amount of nickel ion releases at nickel-titanium archwires. The study was an experimental research with a post-test only control group design. Twenty seven nickel-titanium archwires were divided into three groups, i.e., K group, which were immersed in artificial saliva. P1 was immersed in artificial saliva and 1.5 gram of toothpaste A, and P2 was immersed in artificial saliva, and 1.5 gram of toothpaste B. The samples were incubated (37 °C) for 1 and 1.5 months. Nickel ion released was analyzed using SSA. Two Way ANOVA and Post Hoc LSD test were the statistic test used. The results of this study were the K group which released 0.112 mg/l and 0.685 mg/l, P1 which released 0.093 mg/l and 0.670 mg/l, and P2 which released 0.099 mg/l and 0.657 mg/l. There were differences in toothpaste variations (p = 0.029), differences in immersion time (p = 0.000) and there was no interaction between immersion time and toothpaste variations (p = 0.505) on the amount of nickel ion release. There was a significant difference in K-P1 (p = 0.038), K-P2 (p = 0.013), P1-P2 (p = 0.049). There was a difference in immersion time and toothpaste variation, but there was no interaction between immersion time and toothpaste variation towards the amount of nickel ion releases.


Keywords


nickel ion releases; NiTi archwires; toothpaste variation; the length of immersion

Full Text:

PDF


References

1. Lombo CG, Anindita PS. Uji pelepasan ion nikel dan kromium pada beberapa braket stainless steel yang direndam di air laut. J e-GIGI. 2016; 4(1): 0–4.

2. Hussain HD, Ajith SD, Goel P. Nickel release from stainless steel and nickel titanium archwires - An in vitro study. J Oral Biol Craniofacial Res. 2016; 6(3): 213–218. doi: 10.1016/j.jobcr.2016.06.001

3. Rasyid NI, Pudyani PS, Heryumani J. Pelepasan ion nikel dan kromium kawat Australia dan stainless steel dalam saliva buatan (The release of nickel and chromium ions from Australian wire and stainless steel in artificial saliva). Dental Journal (Majalah Kedokteran Gigi). 2014; 47(3):168-172. doi: 10.20473/j.djmkg.v47.i3.p168-172

4. Syed M, Chopra R, Sachdev V. Allergic reactions to dental materials-a systematic
review. J Clin Diagn Res. 2015; 9(10): ZE04–9. doi: 10.7860/JCDR/2015/15640.6589

5. Azizi A, Jamilian A, Nucci F, Kamali Z, Hosseinikhoo N, Perillo L. Release of metal
ions from round and rectangular NiTi wires. Prog Orthod. 2016; 17(10). doi: 10.1186/s40510-016-0123-3

6. Ornelasari R, Marsudi. Analisa laju korosi pada stainless steel 304 menggunakan metode astm G31-72 pada media air nira aren. JTM. 2015; 1(1): 112-117.

7. Małkiewicz K, Sztogryn M, Mikulewicz M, Wielgus A, Kamiński J, Wierzchoń T. Comparative assessment of the corrosion process of orthodontic archwires made of stainless steel, titanium–molybdenum and nickel–titanium alloys. Archives of Civil and Mechanical Engineering. 2018; 18(3): 941–947. doi: 10.1016/j.acme.2018.01.017

8. Lubis, NT, Lubis HF, Harahap KI. Pelepasan ion nikel kawat ortodonti nikeltitanium setelah
direndam di dalam pasta gigi detergent dan non detergent. Skripsi. Medan: Universitas Sumatera Utara; 2018.

9. Mirhashemi AH, Jahangiri S, Kharrazifard MJ. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes. Prog Orthod. 2018; 19(1): 2–6. doi: 10.1186/s40510-018-0203-7

10. Jamilian A, Moghaddas O, Toopchi S, Perillo L. Comparison of nickel and chromium ions released from stainless steel and niti wires after immersion in Oral B®, Orthokin® and
artificial saliva. J Contemp Dent Pract. 2014; 15(4): 403–406. doi: 10.5005/jp-journals-10024-1552.

11. Wondal LHD, Anindita PS, Tambunan Elita. Perbedaan pelepasan ion nikel (Ni) dan kromium (Cr) kawat ortodonti stainless steel pada perendaman pasta gigi non ortodonti. Jurnal e-Gigi (eG). 2018; 6(2): 66-71. doi: 10.35790/eg.6.2.2018.20150

12. Alli BY, Erinoso OA, Olawuyi AB. Effect of sodium lauryl sulfate on recurrent aphthous
stomatitis: A systematic review. J Oral Pathol Med. 2019; 48(5): 358–364. doi: 10.1111/jop.12845

13. Chaturvedi TP, Upadhayay SN. An overview of orthodontic material degradation in oral
cavity. Indian J Dent Res. 2010; 21(2): 275–284. doi: 10.4103/0970-9290.66648

14. Hazazi DR. Pengaruh pH saliva terhadap pelepasan ion nikel kawat ortodontik nikel titanium. Skripsi. Yogyakarta: Universitas Muhammadiyah Yogyakarta; 2019. 25-26.

15. Willianti E. Pengaruh larutan fluoride terhadap aktivitas amilase saliva. Thesis. Surabaya: Universitas Airlangga; 2015.

16. Sundjono, Saefudin. Pengaruh temperatur dan pH air sadah kalsium sulfat terhadap
korosi pada baja karbon. Majalah Metalurgi. 2014; 29(1): 41-50.

17. Rowe RC, Sheskey PJ, Quinn ME. Handbook of Pharmaceutical Excipients. 6th ed. USA:
Pharmaceutical Press; 2009.

18. Leliana, SDAP. Corrosion rate of titanium orthodontic wire after immersion in artificial
saliva. Stomatognatic (JKG). 2010; 7(1): 56–61.

19. Chitra P, Prashantha GS, Rao A. Effect of fluoride agents on surface characteristics of NiTi wires. An Ex Vivo Invetigation. J Oral Biol Craniofac Res. 2020; 10(4): 435-440.
doi: 10.1016/j.jobcr.2020.07.006

20. Minanga MA, Anindita PS, Juliatri. Pelepasan ion nikel dan kromium braket ortodontik
stainless steel yang direndam dalam obat kumur. Pharmacon J Ilm Farmasi. 2016; 5(1): 135-141.

21. Pataijindachote J, Juntavee N, Viwattanatipa N. Corrosion analysis of orthodontic wires:
an interaction study of wire type, pH and immersion time. Adv Dent & Oral Health.
2018; 10(1): 555780. doi: 10.19080/ADOH.2018.10.555780

22. Tyc O, Heller L, Vronka M, Sittner P. Effect of temperature on fatigue superelastic NiTi wires.
International Journal of Fatigue. 2020; 134: 105470. doi: 10.1016/j.ijfatigue.2020.105470

23. Rochmawati M, Irmawati A, Sunariani J. The difference of salivary ph because of the longterm usage detergent sodium lauryl sulphate 5% toothpaste compared with nondetergent toothpaste. Majalah Ilmu Faal Indonesia. 2008; 8(1): 2008-2010.

24. Trepanier C, Pelton AR. Effect of temperature and pH corrosion resistance of nitinol. Proc
ASM Material & Medical Dev. 2005; 392-397.



DOI: https://doi.org/10.22146/majkedgiind.65712

Article Metrics

Abstract views : 954 | views : 923

Refbacks

  • There are currently no refbacks.




Copyright (c) 2022 Majalah Kedokteran Gigi Indonesia

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.


 

 View My Stats


real
time web analytics