Rancang Bangun Phonocardiograf Berbasis Labview

https://doi.org/10.22146/juliet.v1i1.53811

Ramdani Febrian(1), Budi Sumanto(2*)

(1) Departemen Teknik Elektro dan Informatika, Sekolah Vokasi, Universitas Gadjah Mada
(2) Departemen Teknik Elektro dan Informatika, Sekolah Vokasi, Universitas Gadjah Mada
(*) Corresponding Author

Abstract


Abstract – The aim of this research is to develop a phonocardiograph system to display the signal and information form of the human heart sound examination. The analytical method applied is to use the Fast Fourier Transform (FFT) to determine the frequency of responses of human heart sound signals by using Labview software. The results obtained indicate the system able to display the signal shape of the heart sound, based on ten respondents whose data are taken shows the range of heart sound frequencies is in the range of 145 to 225 Hz with a duration of 81 to 120 bpm.

Keywords: Phonocardiograph, FFT, Labview

Intisari – Tujuan dari penelitian ini adalah membangun sistem phonocardiograf untuk menampilkan bentuk sinyal dan informasi dari pemeriksaan suara jantung manusia. Metode analisis yang diterapkan adalah menggunakan Fast Fourier Transform (FFT) untuk mengetahui frekuensi respon dari sinyal suara jantung manusia dengan memanfaatkan perangkat lunak Labview. Hasil yang diperoleh menunjukkan sistem mampu menampilkan bentuk sinyal dari suara jantung, berdasarkan sepuluh responden yang diambil datanya menunjukkan rentang frekuensi suara jantung berada pada rentang 145 s.d 225 Hz dengan durasi 81 s.d 120 bpm.

Kata kunci : Phonocardiograf, FFT, Labview


Full Text:

PDF


References

[1] Debbal, S.M., Reguig, F.B., 2008, Frequency Analysis of the Heartbeat Sounds, Department of Electronic, Faculty of Science Engineering, University Aboubekr Belkaid, Algeria

[2] Suardi, Wibowo, E.M., Januarifin W., Subakir, I., Wahidin, A.M., 2007, Visualisasi Isyarat Detak Jantung Berbasis Komputer, Prodi T. Elektro, Fak. T. Industri, UAD, Yogyakarta

[3] Cromwell, L., Weibell, F.J., Pfeiffer, E.A., Usselman, L.B., 1973, Biomedical Instrumentation & Measurements, Prentice-hall.inc, Englewood Cliffs, New Jersey

[4] Suprayitno, E.A., dan Anshory, I., Sistem Instrumentasi Sinyal Phonocardiography untuk Analisa Dinamika Jantung, UMS, Sidoarjo

[5] Setiaji, F.D., Santoso, D., Susilo, D., 2011, Rekayasa Stetoskop Elektronik dengan Kemampuan Analisis Bunyi Jantung, Prodi Teknik Elektro, UKSW, Salatiga

[6] Thinkslab Medical LLC, 2015, thinklabs.com, America



DOI: https://doi.org/10.22146/juliet.v1i1.53811

Article Metrics

Abstract views : 1845 | views : 2668

Refbacks

  • There are currently no refbacks.


SINTA 4 accredited based on Decree of the Minister of Research, Technology and Higher Education, Republic of Indonesia Number 225/E/KPT/2022, Vol. 2 No. 1 (2020) - Vol. 6 No. 1 (2025)

e-ISSN: 2746-2536