Indexing metadata

The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)


 
Dublin Core PKP Metadata Items Metadata for this Document
 
1. Title Title of document The Utilization of Nitrogen Gas as a Carrier Gas in the Determination of Hg Ions Using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS)
 
2. Creator Author's name, affiliation, country Aman Sentosa Panggabean; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Mulawarman University, Jl. Barong Tongkok No.4 Kampus Gn. Kelua Samarinda 75123, Indonesia; Indonesia
 
2. Creator Author's name, affiliation, country Subur P Pasaribu; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Mulawarman University, Jl. Barong Tongkok No.4 Kampus Gn. Kelua Samarinda 75123, Indonesia; Indonesia
 
2. Creator Author's name, affiliation, country Farida Kristiana; Department of Chemistry, Faculty of Mathematics and Natural Sciences, Mulawarman University, Jl. Barong Tongkok No.4 Kampus Gn. Kelua Samarinda 75123, Indonesia; Indonesia
 
3. Subject Discipline(s)
 
3. Subject Keyword(s) Hg; carrier gas; nitrogen; CV-AAS
 
4. Description Abstract The research about utilization of nitrogen gas as a carrier gas in the determination of Hg ions by using Cold Vapor-Atomic Absorption Spectrophotometer (CV-AAS) method has been conducted. To optimize the measurement results, several parameters that affect hydride generator have been studied. Some specified important parameters are SnCl2 concentration as reductant, acid concentration, and the analytical performance such as repeatability and reproducibility (% RSD), linearity (r), limits of detection (LOD) and limits of quantitation (LOQ), and accuracy have been studied. The results of the research showed that the nitrogen gas can be used instead of argon gas as a carrier gas. It was shown by the repeatability values as % RSD < 2/3 CV Horwitz values, the LOD was 0.0338 µg/L and the LOQ was 0.0838 µg/L. The accuracy of this method was well shown by a recovery percentage was 102.24%. Based on the result of this research, the nitrogen gas can be used as a carrier gas for the determination of Hg ions by using the CV-AAS method with valid results.
 
5. Publisher Organizing agency, location Universitas Gadjah Mada
 
6. Contributor Sponsor(s) PT Badak LNG Bontang Kalimantan Timur
 
7. Date (YYYY-MM-DD) 2018-02-01
 
8. Type Status & genre Peer-reviewed Article
 
8. Type Type
 
9. Format File format Full Text PDF
 
10. Identifier Uniform Resource Identifier https://jurnal.ugm.ac.id/ijc/article/view/23092
 
10. Identifier Digital Object Identifier (DOI) https://doi.org/10.22146/ijc.23092
 
11. Source Title; vol., no. (year) Indonesian Journal of Chemistry; Article in press
 
12. Language English=en en
 
13. Relation Supp. Files
 
14. Coverage Geo-spatial location, chronological period, research sample (gender, age, etc.)
 
15. Rights Copyright and permissions Copyright (c) 2018 Indonesian Journal of Chemistry
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.